Set Graphic Name Prefix
| Parameter |
Type |
Range |
Description |
| prefix |
string |
up to 4 ASCII chars (0x01 .. 0xFF) |
string to be prefix |
Sets a prefix of case-sensitive string characters, which will be put in front of any subsequently sent graphic name (see Display Local Graphic).
Note
- This functionality can be used to support multiple languages without conditional commands or macros. For example, if the graphic names for the English language are prefixed with "en_" and for the German language with "de_", the command
would display the graphic "en_graphic" or "de_graphic", dependent on the prior defined graphic prefix.
- When addressing graphics by index, an offset can be used to realize language switching (see Set Graphic Offset).
- Remove any previously set Graphic Name Prefix by entering an empty string as prefix:
- The default value for prefix is an empty string. It will be automatically set to default on startup and by the commands Reset All or Reboot Panel Controller if the "Extras on Reset" option on the "Settings" page of iLCD Manager XE is set to "Clear". Selecting "Keep" allows for using the reset commands without loosing e.g. the selected language. This setting is ignored in firmware versions < 3.02.
Set the graphic name prefix to "en_" and will subsequently only set graphics that start with these characters.
Not supported by: DPC3020, DPC2060, DPC10xx
See also: